Ventilation CFM Calculator

Calculate the exhaust fan size needed to properly ventilate your grow room

Room & Equipment Setup
Enter your grow room dimensions and lighting details

Room Volume: 112 cubic feet

15°C (cool)25°C (warm)35°C (hot)
Ventilation Requirements
For 1x 600W HPS in a 4×4×7ft space
Minimum CFM Required
170
without carbon filter
With Carbon Filter
213
+25% for filter resistance
Recommended Fan
4-inch inline fan
1.5 air exchanges/min

Heat Output

Your 600W HPS setup produces approximately 420 watts (1433 BTU/hr) of heat that must be removed.

Fan CFM by Duct Size

Smaller ducts restrict airflow. If using a smaller duct, you need a higher-rated fan:

Duct SizeAirflow EfficiencyFan Rating Needed
4-inch~50%340 CFM fan
6-inch~75%227 CFM fan
8-inch (recommended)~100%170 CFM fan

HPS Heat Management Tips

  • • Air-cooled hoods can reduce room heat by 30-40%
  • • Place ballast outside the grow space if possible
  • • Consider running lights at night when ambient temps are lower
  • • Ensure intake is from a cool source (not the same room)
  • • LED alternatives produce 50-60% less heat for equivalent output

General Guidelines

  • • Aim for 1-3 complete air exchanges per minute
  • • Always buy a fan rated higher than minimum—you can use a speed controller
  • • Ensure passive intake is 2-4x the size of exhaust opening
  • • Negative pressure (exhaust > intake) helps control odors